Project Details


Northeastern Illinois University CCICS Building
CCICS – North Elevation – 700 E. Oakwood Blvd
PROBLEM
The structure's north elevation masonry parapet wall and cornice was severely deteriorated which led to the following:
- Spalling brick masonry on the outer wythe of the masonry parapet wall
- Shifting of brick masonry in the decorative cornice
- Cracked, open, and deteriorated mortar joints in the brick masonry, both on the inner and outer parapet wall
- Shifting of coping stones and open sealant joints
- Open sealant joints in the counter-flashing and roofing at the interior of the parapet wall
SOLUTION
BAMR addressed the damaged structure by reconstructing it in its entirety including:
- Five wythes of masonry were demolished and reconstructed
- Masonry cornice was reconstructed in its original pattern
- New theu-wall flashings at coping stones were installed
- New stainless steel masonry anchors were used to anchor the brick and copings
- New sealant were installed at all skyward facing joints
- New counter-flashing, roofing, and sealant were installed at the backside of the parapet wall
CLIENT
Northeastern Illinois University
PROJECT SIZE
Not Applicable
ENGINEER / ARCHITECT
Klein & Hoffman, Inc. http://www.kleinandhoffman.com
ROLE
Masonry Restoration Contractor
LOCATION
Chicago, IL
MARKET
Educational/Institutional
Municipal