PROBLEM

The structure's north elevation masonry parapet wall and cornice was severely deteriorated which led to the following:

  • Spalling brick masonry on the outer wythe of the masonry parapet wall
  • Shifting of brick masonry in the decorative cornice
  • Cracked, open, and deteriorated mortar joints in the brick masonry, both on the inner and outer parapet wall
  • Shifting of coping stones and open sealant joints
  • Open sealant joints in the counter-flashing and roofing at the interior of the parapet wall

SOLUTION

BAMR addressed the damaged structure by reconstructing it in its entirety including:

  • Five wythes of masonry were demolished and reconstructed
  • Masonry cornice was reconstructed in its original pattern
  • New theu-wall flashings at coping stones were installed
  • New stainless steel masonry anchors were used to anchor the brick and copings
  • New sealant were installed at all skyward facing joints
  • New counter-flashing, roofing, and sealant were installed at the backside of the parapet wall

CLIENT

Northeastern Illinois University

PROJECT SIZE

Not Applicable

ENGINEER / ARCHITECT

Klein & Hoffman, Inc. http://www.kleinandhoffman.com

ROLE

Masonry Restoration Contractor

LOCATION

Chicago, IL

MARKET

Educational/Institutional

Municipal

Honors and Awards
ENR's Top 400
253
Number of Years in business
122
Percent of Repeat Clients
75
Safety EMR Rating
0.80
LEED Accredited Professionals
27
Contractor Score
2026
Subcontrators